Synergy H1
Hybrid Multi-Mode Reader
Synergy™ H1 is a configurable multi-mode microplate reader. Choose monochromator-based optics for flexibility, filter-based optics for sensitivity, or both…BioTek’s patented Hybrid Technology™ offers high-performance and applications versatility in a modular platform to expand as your laboratory’s needs change. Top and bottom fluorescence intensity, UV-visible absorbance and luminescence detection are available to meet many life science research requirements.
- Cost-effective hybrid offering excellent sensitivity, flexibility and value
- Modular and upgradable: choose the modes you need now, add as needs change
- Patented Hybrid Technology: sensitivity of filters and flexibility of monochromators
- Micro-volume nucleic acid and protein quantification with the Take3 Micro-Volume Plate
- Live cell assay friendly with temperature control and CO2/O2 control
APPLICATIONS
With quadruple monochromators and optional gas control and reagent injection, Synergy H1 can be used for a wide range of applications in fluorescence, luminescence, UV-Vis and more.
- Cell based assays
- Biomarker Assays
- Micro-volume analysis of nucleic acid and protein
- Kinetic assays
- Micro-volume nucleic acid and protein quantification with the Take3 Micro-Volume Plate
Effect of increasing levels of ethanol on yeast growth
HTRF® ratios for AMD3011 and SDF1-alpha
Micro-volume (2 µL) quantification of up to 48 samples with Take3 Plate
FEATURES
Cost-effective hybrid
Modular, upgradable design
Patented Hybrid optics
Micro-volume quantification
Live cell assay friendly environment
GENERAL
Detection modes | UV-Vis absorbance Fluorescence intensity Luminescence Fluorescence polarization Time-resolved fluorescence |
Read methods | Endpoint, kinetic, spectral scanning, well area scanning |
Microplate types | 6- to 384-well plates |
Other labware supported | Petri and cell culture dishes Take3 Micro-Volume Plates |
Temperature control | 4-Zone™ incubation to 45 °C with Condensation Control™ +0.2 °C at 37 °C |
Shaking | Linear, orbital, double orbital |
Software | Gen5™ Data Analysis Software Gen5 Secure for 21 CFR Part 11 compliance (option) |
Automation | BioStack and 3rd party automation compatible BioSpa 8 Automated Incubator compatible |
CO2 and O2 control (option) | Range: 0 – 20% (CO2); 1 – 19% (O2) Control Resolution: +0.1% (CO2 and O2) Stability: +0.2% at 5% CO2; +0.2% at 1% O2 Models for both CO2 and O2 or CO2 only are available |
ABSORBANCE
Light source | Xenon flash |
Detector | photodiode |
Wavelength selection | monochromator |
Wavelength range | 230 – 999 nm, 1 nm increments |
Monochromator bandwidth | 4 nm (230-285 nm), 8 nm (>285 nm) |
Dynamic range | 0 – 4.0 OD |
Resolution | 0.0001 OD |
Pathlength correction | yes |
Monochromator wavelength accuracy | ±2 nm |
Monochromator wavelength repeatability | ±0.2 nm |
OD accuracy | <1% at 2.0 OD <3% at 3.0 OD |
OD linearity | <1% from 0 to 3.0 OD |
OD repeatability | <0.5% at 2.0 OD |
Stray light | 0.03% at 230 nm |
Reading speed (kinetic) | 96 wells: 11 seconds 384 wells: 22 seconds |
FLUORESCENCE INTENSITY
Light source | Xenon flash |
Detector | PMT for monochromator system PMT for filter system |
Wavelength selection | Quad monochromators (top/bottom) Filters (top) |
Wavelength range | Monochromators: 250 – 700 nm (850 nm option) Filters: 200 – 700 nm (850 nm option) |
Monochromator bandwidth | Fixed, 16 nm |
Dynamic range | 7 decades |
Sensitivity | Filters: Fluorescein 0.25 pM (0.025 fmol/well, 384-well plate) Quad Monochromator: |
Reading speed (kinetic) | 96 wells: 11 seconds 384 wells: 22 seconds |
LUMINESCENCE
Wavelength range | 300 – 700 nm |
Dynamic range | >6 decades |
Sensitivity | Monos: 20 amol ATP (flash) Filters: 10 amol ATP (flash), 100 amol (glow) |
FLUORESCENCE POLARIZATION
Light source | Xenon flash |
Detector | PMT |
Wavelength selection | Filters |
Wavelength range | 280 – 700 nm (850 nm option) |
Sensitivity | 1.2 mP standard deviation at 1 nm fluorescein |
TIME-RESOLVED FLUORESCENCE
Light source | Xenon flash |
Detector | PMT |
Wavelength selection | Quad monochromators (secondary mode) Filters (top) |
Wavelength range | Filters: 200 – 700 nm (850 nm option) |
Sensitivity | Filters: Europium 40 fM (4 amol/well, 384-well plate) Monos: Europium 1200 fM (120 amol/well, 384-well plate) |
REAGENT DISPENSERS
Supported detection modes | All modes |
Number | 2 syringe pumps |
Supported labware | 6- to 384-well microplates, Petri dishes |
Dead volume | 1.1 mL with back flush |
Dispense volume | 5 – 1000 µL in 1 µL increment |
Dispense accuracy | ±1 µL or 2% |
Dispense precision | <2% at 50-200 µL |
PHYSICAL CHARACTERISTICS
Power | 130 Watts maximum consumption. |
Dimensions | 15.4″W 18.6″D 12.9″H (39.1 x 47.2 x 32.8 cm) |
Weight | 50 lbs (22.5 kg) |
REGULATORY
Regulatory | CE and TUV marked. RoHS Compliant. Models for In Vitro Diagnostic use are available. |
Part #
|
H1M
|
H1F
|
H1MF
|
---|---|---|---|
Monochromator fluorescence
|
•
|
|
•
|
Monochromator absorbance
|
•
|
|
•
|
Full-light luminescence
|
•
|
•
|
•
|
Filter/dichroic fluorescence
|
•
|
•
|
|
Fluorescence polarization
|
•
|
•
|
|
Time resolved fluorescence
|
• *
|
•
|
•
|
Filtered luminescence
|
•
|
•
|
|
Temperature control to 45°C
|
•
|
•
|
•
|
Gen5 data analysis software
|
•
|
•
|
•
|
Gas Controller Compatible Configurations**
|
H1MG | H1FG | H1MFG |
* Secondary mode
** These configurations have the same features as the non- Gas Controller Compatible configurations in the chart above. Gas Controller sold separately.
All configurations are compatible with the Dual Reagent Injector Module, sold separately.
Reviews